Units 690V Line Voltage
SKU: bc-654
$1,613.82
Currently out of stock — contact us for lead times
Description
Main range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 11 kW at 660 V for standard applications11 kW at 690 V for severe applications15 kW at 690 V for standard applications3 kW at 230 V for severe applications4 kW at 230 V for standard applications9 kW at 500 V for standard applications9 kW at 525 V for standard applications9 kW at 660 V for severe applications7.5 kW at 400 V for standard applications7.5 kW at 440 V for standard applications7.5 kW at 500 V for severe applications7.5 kW at 525 V for severe applications5.5 kW at 400 V for severe applications5.5 kW at 440 V for severe applications motor power hp 10 hp at 460 V for standard applications10 hp at 575 V for severe applications15 hp at 575 V for standard applications2 hp at 208 V for severe applications3 hp at 208 V for standard applications3 hp at 230 V for severe applications5 hp at 230 V for standard applications7.5 hp at 460 V for severe applications power dissipation in W 46 W for standard applications59 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 17 A for connection in the motor supply line for severe applications17 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 275 mm width 160 mm depth 190 mm net weight 4.9 kg Motor power range AC-3 2.2…3 kW at 200…240 V 3 phases4…6 kW at 200…240 V 3 phases7…11 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48D22Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 11 kW at 400 V for standard applications11 kW at 440 V for standard applications11 kW at 500 V for standard applications11 kW at 525 V for standard applications11 kW at 660 V for severe applications15 kW at 660 V for standard applications15 kW at 690 V for severe applications4 kW at 230 V for severe applications9 kW at 500 V for severe applications9 kW at 525 V for severe applications7.5 kW at 400 V for severe applications7.5 kW at 440 V for severe applications18.5 kW at 690 V for standard applications5.5 kW at 230 V for standard applications motor power hp 10 hp at 460 V for severe applications15 hp at 460 V for standard applications15 hp at 575 V for severe applications20 hp at 575 V for standard applications3 hp at 208 V for severe applications5 hp at 208 V for standard applications5 hp at 230 V for severe applications7.5 hp at 230 V for standard applications power dissipation in W 59 W for standard applications74 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 22 A for connection in the motor supply line for severe applications22 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 275 mm width 160 mm depth 190 mm net weight 4.9 kg Motor power range AC-3 7…11 kW at 380…440 V 3 phases4…6 kW at 200…240 V 3 phases7…11 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48D32Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 11 kW at 400 V for severe applications11 kW at 440 V for severe applications11 kW at 500 V for severe applications11 kW at 525 V for severe applications15 kW at 400 V for standard applications15 kW at 440 V for standard applications15 kW at 660 V for severe applications22 kW at 660 V for standard applications22 kW at 690 V for standard applications7.5 kW at 230 V for standard applications18.5 kW at 500 V for standard applications18.5 kW at 525 V for standard applications18.5 kW at 690 V for severe applications5.5 kW at 230 V for severe applications motor power hp 10 hp at 230 V for standard applications15 hp at 460 V for severe applications20 hp at 460 V for standard applications20 hp at 575 V for severe applications25 hp at 575 V for standard applications5 hp at 208 V for severe applications7.5 hp at 208 V for standard applications7.5 hp at 230 V for severe applications power dissipation in W 104 W for standard applications74 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 32 A for connection in the motor supply line for severe applications32 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 275 mm width 160 mm depth 190 mm net weight 4.9 kg Motor power range AC-3 7…11 kW at 200…240 V 3 phases15…25 kW at 380…440 V 3 phases4…6 kW at 200…240 V 3 phases15…25 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48D38Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 15 kW at 400 V for severe applications15 kW at 440 V for severe applications22 kW at 500 V for standard applications22 kW at 525 V for standard applications22 kW at 660 V for severe applications22 kW at 690 V for severe applications30 kW at 660 V for standard applications30 kW at 690 V for standard applications9 kW at 230 V for standard applications7.5 kW at 230 V for severe applications18.5 kW at 400 V for standard applications18.5 kW at 440 V for standard applications18.5 kW at 500 V for severe applications18.5 kW at 525 V for severe applications motor power hp 10 hp at 208 V for standard applications10 hp at 230 V for severe applications20 hp at 460 V for severe applications25 hp at 460 V for standard applications25 hp at 575 V for severe applications30 hp at 575 V for standard applications7.5 hp at 208 V for severe applications power dissipation in W 116 W for standard applications99 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 38 A for connection in the motor supply line for severe applications38 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 275 mm width 160 mm depth 190 mm net weight 4.9 kg Motor power range AC-3 7…11 kW at 200…240 V 3 phases15…25 kW at 380…440 V 3 phases15…25 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48D47Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 11 kW at 230 V for standard applications22 kW at 400 V for standard applications22 kW at 440 V for standard applications22 kW at 500 V for severe applications22 kW at 525 V for severe applications30 kW at 500 V for standard applications30 kW at 525 V for standard applications30 kW at 660 V for severe applications30 kW at 690 V for severe applications37 kW at 660 V for standard applications37 kW at 690 V for standard applications9 kW at 230 V for severe applications18.5 kW at 400 V for severe applications18.5 kW at 440 V for severe applications motor power hp 10 hp at 208 V for severe applications15 hp at 230 V for standard applications25 hp at 460 V for severe applications30 hp at 460 V for standard applications30 hp at 575 V for severe applications40 hp at 575 V for standard applications power dissipation in W 116 W for standard applications142 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 47 A for connection in the motor supply line for severe applications47 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 275 mm width 160 mm depth 190 mm net weight 4.9 kg Motor power range AC-3 7…11 kW at 200…240 V 3 phases15…25 kW at 380…440 V 3 phases15…25 kW at 480…500 V 3 phases30…50 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48D62Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 11 kW at 230 V for severe applications15 kW at 230 V for standard applications22 kW at 400 V for severe applications22 kW at 440 V for severe applications30 kW at 400 V for standard applications30 kW at 440 V for standard applications30 kW at 500 V for severe applications30 kW at 525 V for severe applications37 kW at 500 V for standard applications37 kW at 525 V for standard applications37 kW at 660 V for severe applications37 kW at 690 V for severe applications45 kW at 660 V for standard applications45 kW at 690 V for standard applications motor power hp 15 hp at 208 V for standard applications15 hp at 230 V for severe applications20 hp at 230 V for standard applications30 hp at 460 V for severe applications40 hp at 460 V for standard applications40 hp at 575 V for severe applications50 hp at 575 V for standard applications power dissipation in W 153 W for standard applications201 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 62 A for connection in the motor supply line for standard applications62 A for connection in the motor supply line for severe applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 290 mm width 190 mm depth 235 mm net weight 8.3 kg Motor power range AC-3 15…25 kW at 200…240 V 3 phases30…50 kW at 380…440 V 3 phases30…50 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48D75Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 15 kW at 230 V for severe applications30 kW at 400 V for severe applications30 kW at 440 V for severe applications37 kW at 400 V for standard applications37 kW at 440 V for standard applications37 kW at 500 V for severe applications37 kW at 525 V for severe applications45 kW at 500 V for standard applications45 kW at 525 V for standard applications45 kW at 660 V for severe applications45 kW at 690 V for severe applications55 kW at 660 V for standard applications55 kW at 690 V for standard applications18.5 kW at 230 V for standard applications motor power hp 15 hp at 208 V for severe applications20 hp at 208 V for standard applications20 hp at 230 V for severe applications25 hp at 230 V for standard applications40 hp at 460 V for severe applications50 hp at 460 V for standard applications50 hp at 575 V for severe applications60 hp at 575 V for standard applications power dissipation in W 201 W for standard applications245 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 75 A for connection in the motor supply line for severe applications75 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 290 mm width 190 mm depth 235 mm net weight 8.3 kg Motor power range AC-3 15…25 kW at 200…240 V 3 phases30…50 kW at 380…440 V 3 phases55…100 kW at 480…500 V 3 phases30…50 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48D88Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 22 kW at 230 V for standard applications37 kW at 400 V for severe applications37 kW at 440 V for severe applications45 kW at 400 V for standard applications45 kW at 440 V for standard applications45 kW at 500 V for severe applications45 kW at 525 V for severe applications55 kW at 500 V for standard applications55 kW at 525 V for standard applications55 kW at 660 V for severe applications55 kW at 690 V for severe applications75 kW at 660 V for standard applications75 kW at 690 V for standard applications18.5 kW at 230 V for severe applications motor power hp 20 hp at 208 V for severe applications25 hp at 208 V for standard applications25 hp at 230 V for severe applications30 hp at 230 V for standard applications50 hp at 460 V for severe applications60 hp at 460 V for standard applications60 hp at 575 V for severe applications75 hp at 575 V for standard applications power dissipation in W 245 W for standard applications290 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 88 A for connection in the motor supply line for severe applications88 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 290 mm width 190 mm depth 235 mm net weight 8.3 kg Motor power range AC-3 15…25 kW at 200…240 V 3 phases30…50 kW at 380…440 V 3 phases55…100 kW at 480…500 V 3 phases30…50 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C11Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 22 kW at 230 V for severe applications30 kW at 230 V for standard applications45 kW at 400 V for severe applications45 kW at 440 V for severe applications55 kW at 400 V for standard applications55 kW at 440 V for standard applications55 kW at 500 V for severe applications55 kW at 525 V for severe applications75 kW at 500 V for standard applications75 kW at 525 V for standard applications75 kW at 660 V for severe applications75 kW at 690 V for severe applications90 kW at 660 V for standard applications90 kW at 690 V for standard applications motor power hp 100 hp at 575 V for standard applications25 hp at 208 V for severe applications30 hp at 208 V for standard applications30 hp at 230 V for severe applications40 hp at 230 V for standard applications60 hp at 460 V for severe applications75 hp at 460 V for standard applications75 hp at 575 V for severe applications power dissipation in W 252 W for standard applications322 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 110 A for connection in the motor supply line for standard applications110 A for connection in the motor supply line for severe applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 290 mm width 190 mm depth 235 mm net weight 8.3 kg Motor power range AC-3 15…25 kW at 200…240 V 3 phases30…50 kW at 200…240 V 3 phases55…100 kW at 380…440 V 3 phases55…100 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C14Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 110 kW at 660 V for standard applications110 kW at 690 V for standard applications30 kW at 230 V for severe applications37 kW at 230 V for standard applications55 kW at 400 V for severe applications55 kW at 440 V for severe applications75 kW at 400 V for standard applications75 kW at 440 V for standard applications75 kW at 500 V for severe applications75 kW at 525 V for severe applications90 kW at 500 V for standard applications90 kW at 525 V for standard applications90 kW at 660 V for severe applications90 kW at 690 V for severe applications motor power hp 100 hp at 460 V for standard applications100 hp at 575 V for severe applications125 hp at 575 V for standard applications30 hp at 208 V for severe applications40 hp at 208 V for standard applications40 hp at 230 V for severe applications50 hp at 230 V for standard applications75 hp at 460 V for severe applications power dissipation in W 306 W for standard applications391 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 140 A for connection in the motor supply line for severe applications140 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 340 mm width 200 mm depth 265 mm net weight 12.4 kg Motor power range AC-3 30…50 kW at 200…240 V 3 phases55…100 kW at 380…440 V 3 phases55…100 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C17Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 110 kW at 500 V for standard applications110 kW at 525 V for standard applications110 kW at 660 V for severe applications110 kW at 690 V for severe applications132 kW at 660 V for standard applications160 kW at 690 V for standard applications37 kW at 230 V for severe applications45 kW at 230 V for standard applications75 kW at 400 V for severe applications75 kW at 440 V for severe applications90 kW at 400 V for standard applications90 kW at 440 V for standard applications90 kW at 500 V for severe applications90 kW at 525 V for severe applications motor power hp 100 hp at 460 V for severe applications125 hp at 460 V for standard applications125 hp at 575 V for severe applications150 hp at 575 V for standard applications40 hp at 208 V for severe applications50 hp at 208 V for standard applications50 hp at 230 V for severe applications60 hp at 230 V for standard applications power dissipation in W 391 W for standard applications479 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 170 A for connection in the motor supply line for severe applications170 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 340 mm width 200 mm depth 265 mm net weight 12.4 kg Motor power range AC-3 30…50 kW at 200…240 V 3 phases55…100 kW at 380…440 V 3 phases110…220 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C21Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 110 kW at 400 V for standard applications110 kW at 440 V for standard applications110 kW at 500 V for severe applications110 kW at 525 V for severe applications132 kW at 500 V for standard applications132 kW at 525 V for standard applications132 kW at 660 V for severe applications160 kW at 660 V for standard applications160 kW at 690 V for severe applications200 kW at 690 V for standard applications45 kW at 230 V for severe applications55 kW at 230 V for standard applications90 kW at 400 V for severe applications90 kW at 440 V for severe applications motor power hp 125 hp at 460 V for severe applications150 hp at 460 V for standard applications150 hp at 575 V for severe applications200 hp at 575 V for standard applications50 hp at 208 V for severe applications60 hp at 208 V for standard applications60 hp at 230 V for severe applications75 hp at 230 V for standard applications power dissipation in W 468 W for standard applications580 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 210 A for connection in the motor supply line for severe applications210 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 380 mm width 320 mm depth 265 mm net weight 18.2 kg Motor power range AC-3 30…50 kW at 200…240 V 3 phases55…100 kW at 200…240 V 3 phases110…220 kW at 380…440 V 3 phases110…220 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C25Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 110 kW at 400 V for severe applications110 kW at 440 V for severe applications132 kW at 400 V for standard applications132 kW at 440 V for standard applications132 kW at 500 V for severe applications132 kW at 525 V for severe applications160 kW at 500 V for standard applications160 kW at 525 V for standard applications160 kW at 660 V for severe applications200 kW at 690 V for severe applications220 kW at 660 V for standard applications250 kW at 690 V for standard applications55 kW at 230 V for severe applications75 kW at 230 V for standard applications motor power hp 100 hp at 230 V for standard applications150 hp at 460 V for severe applications200 hp at 460 V for standard applications200 hp at 575 V for severe applications250 hp at 575 V for standard applications60 hp at 208 V for severe applications75 hp at 208 V for standard applications75 hp at 230 V for severe applications power dissipation in W 580 W for standard applications695 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 250 A for connection in the motor supply line for severe applications250 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 380 mm width 320 mm depth 265 mm net weight 18.2 kg Motor power range AC-3 55…100 kW at 200…240 V 3 phases110…220 kW at 380…440 V 3 phases110…220 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C32Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 132 kW at 400 V for severe applications132 kW at 440 V for severe applications160 kW at 400 V for standard applications160 kW at 440 V for standard applications160 kW at 500 V for severe applications160 kW at 525 V for severe applications220 kW at 500 V for standard applications220 kW at 525 V for standard applications220 kW at 660 V for severe applications250 kW at 660 V for standard applications250 kW at 690 V for severe applications315 kW at 690 V for standard applications75 kW at 230 V for severe applications90 kW at 230 V for standard applications motor power hp 100 hp at 208 V for standard applications100 hp at 230 V for severe applications125 hp at 230 V for standard applications200 hp at 460 V for severe applications250 hp at 460 V for standard applications250 hp at 575 V for severe applications300 hp at 575 V for standard applications75 hp at 208 V for severe applications power dissipation in W 695 W for standard applications902 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 320 A for connection in the motor supply line for severe applications320 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 380 mm width 320 mm depth 265 mm net weight 18.2 kg Motor power range AC-3 55…100 kW at 200…240 V 3 phases110…220 kW at 380…440 V 3 phases110…220 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C41Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 110 kW at 230 V for standard applications160 kW at 400 V for severe applications160 kW at 440 V for severe applications220 kW at 400 V for standard applications220 kW at 440 V for standard applications220 kW at 500 V for severe applications220 kW at 525 V for severe applications250 kW at 500 V for standard applications250 kW at 525 V for standard applications250 kW at 660 V for severe applications315 kW at 690 V for severe applications355 kW at 660 V for standard applications400 kW at 690 V for standard applications90 kW at 230 V for severe applications motor power hp 100 hp at 208 V for severe applications125 hp at 208 V for standard applications125 hp at 230 V for severe applications150 hp at 230 V for standard applications250 hp at 460 V for severe applications300 hp at 460 V for standard applications300 hp at 575 V for severe applications350 hp at 575 V for standard applications power dissipation in W 1017 W for standard applications1339 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 410 A for connection in the motor supply line for severe applications410 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 670 mm width 400 mm depth 300 mm net weight 51.4 kg Motor power range AC-3 55…100 kW at 200…240 V 3 phases110…220 kW at 380…440 V 3 phases110…220 kW at 200…240 V 3 phases250…500 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C48Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 110 kW at 230 V for severe applications132 kW at 230 V for standard applications220 kW at 400 V for severe applications220 kW at 440 V for severe applications250 kW at 400 V for standard applications250 kW at 440 V for standard applications250 kW at 500 V for severe applications250 kW at 525 V for severe applications315 kW at 500 V for standard applications315 kW at 525 V for standard applications355 kW at 660 V for severe applications400 kW at 660 V for standard applications400 kW at 690 V for severe applications500 kW at 690 V for standard applications motor power hp 125 hp at 208 V for severe applications150 hp at 208 V for standard applications150 hp at 230 V for severe applications300 hp at 460 V for severe applications350 hp at 460 V for standard applications350 hp at 575 V for severe applications400 hp at 575 V for standard applications power dissipation in W 1172 W for standard applications1386 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 480 A for connection in the motor supply line for severe applications480 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 670 mm width 400 mm depth 300 mm net weight 51.4 kg Motor power range AC-3 110…220 kW at 380…440 V 3 phases110…220 kW at 200…240 V 3 phases250…500 kW at 380…440 V 3 phases250…500 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C59Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 132 kW at 230 V for severe applications160 kW at 230 V for standard applications250 kW at 400 V for severe applications250 kW at 440 V for severe applications315 kW at 400 V for standard applications315 kW at 500 V for severe applications315 kW at 525 V for severe applications355 kW at 440 V for standard applications400 kW at 500 V for standard applications400 kW at 525 V for standard applications400 kW at 660 V for severe applications500 kW at 690 V for severe applications560 kW at 660 V for standard applications560 kW at 690 V for standard applications motor power hp 150 hp at 208 V for severe applications200 hp at 230 V for standard applications350 hp at 460 V for severe applications400 hp at 460 V for standard applications400 hp at 575 V for severe applications500 hp at 575 V for standard applications power dissipation in W 1386 W for standard applications1731 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 590 A for connection in the motor supply line for standard applications590 A for connection in the motor supply line for severe applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 670 mm width 400 mm depth 300 mm net weight 51.4 kg Motor power range AC-3 110…220 kW at 200…240 V 3 phases250…500 kW at 380…440 V 3 phases250…500 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48C66Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 160 kW at 230 V for severe applications315 kW at 400 V for severe applications355 kW at 400 V for standard applications355 kW at 440 V for severe applications400 kW at 440 V for standard applications400 kW at 500 V for severe applications400 kW at 525 V for severe applications560 kW at 660 V for severe applications560 kW at 690 V for severe applications630 kW at 660 V for standard applications630 kW at 690 V for standard applications motor power hp 200 hp at 208 V for standard applications200 hp at 230 V for severe applications250 hp at 230 V for standard applications400 hp at 460 V for severe applications500 hp at 460 V for standard applications500 hp at 575 V for severe applications600 hp at 575 V for standard applications power dissipation in W 1731 W for standard applications1958 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 660 A for connection in the motor supply line for severe applications660 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 670 mm width 400 mm depth 300 mm net weight 51.4 kg Motor power range AC-3 110…220 kW at 200…240 V 3 phases250…500 kW at 380…440 V 3 phases motor starter type Soft starter Main - ATS48C79Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 220 kW at 230 V for standard applications355 kW at 400 V for severe applications400 kW at 400 V for standard applications400 kW at 440 V for severe applications500 kW at 440 V for standard applications500 kW at 500 V for standard applications500 kW at 525 V for standard applications630 kW at 660 V for severe applications630 kW at 690 V for severe applications710 kW at 660 V for standard applications710 kW at 690 V for standard applications motor power hp 200 hp at 208 V for severe applications250 hp at 208 V for standard applications250 hp at 230 V for severe applications300 hp at 230 V for standard applications500 hp at 460 V for severe applications600 hp at 460 V for standard applications600 hp at 575 V for severe applications800 hp at 575 V for standard applications power dissipation in W 2073 W for standard applications2537 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 790 A for connection in the motor supply line for standard applications790 A for connection in the motor supply line for severe applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 890 mm width 770 mm depth 315 mm net weight 115 kg Motor power range AC-3 110…220 kW at 200…240 V 3 phases250…500 kW at 380…440 V 3 phases250…500 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48M10Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 220 kW at 230 V for severe applications250 kW at 230 V for standard applications400 kW at 400 V for severe applications500 kW at 400 V for standard applications500 kW at 440 V for severe applications500 kW at 500 V for severe applications500 kW at 525 V for severe applications630 kW at 440 V for standard applications630 kW at 500 V for standard applications630 kW at 525 V for standard applications710 kW at 660 V for severe applications710 kW at 690 V for severe applications900 kW at 660 V for standard applications900 kW at 690 V for standard applications motor power hp 1000 hp at 575 V for standard applications250 hp at 208 V for severe applications300 hp at 230 V for severe applications350 hp at 208 V for standard applications350 hp at 230 V for standard applications600 hp at 460 V for severe applications800 hp at 460 V for standard applications800 hp at 575 V for severe applications power dissipation in W 2225 W for standard applications2865 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 1000 A for connection in the motor supply line for standard applications1000 A for connection in the motor supply line for severe applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 890 mm width 770 mm depth 315 mm net weight 115 kg Motor power range AC-3 110…220 kW at 200…240 V 3 phases250…500 kW at 380…440 V 3 phases250…500 kW at 480…500 V 3 phases250…500 kW at 200…240 V 3 phases560…900 kW at 380…440 V 3 phases560…900 kW at 480…500 V 3 phases motor starter type Soft starter Main - ATS48M12Y range of product Altistart 48 product or component type Soft starter product destination Asynchronous motors product specific application Heavy duty industry and pumps device short name ATS48 power supply voltage 208...690 V - 15...10 % motor power kW 250 kW at 230 V for severe applications355 kW at 230 V for standard applications500 kW at 400 V for severe applications630 kW at 400 V for standard applications630 kW at 440 V for severe applications630 kW at 500 V for severe applications630 kW at 525 V for severe applications710 kW at 440 V for standard applications800 kW at 500 V for standard applications800 kW at 525 V for standard applications900 kW at 660 V for severe applications900 kW at 690 V for severe applications motor power hp 1000 hp at 460 V for standard applications1000 hp at 575 V for severe applications1200 hp at 575 V for standard applications350 hp at 208 V for severe applications350 hp at 230 V for severe applications400 hp at 208 V for standard applications450 hp at 230 V for standard applications800 hp at 460 V for severe applications power dissipation in W 2865 W for standard applications3497 W for standard applications utilisation category AC-53A type of start Start with torque control (current limited to 5 In) Icl nominal current 1200 A for connection in the motor supply line for severe applications1200 A for connection in the motor supply line for standard applications Complementary assembly style With heat sink function available External bypass (optional) power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5...63 Hz device connection In the motor supply line discrete output number 2 discrete output type (LO1) logic output 0 V common configurable(LO2) logic output 0 V common configurable(R1) relay outputs fault relay NO(R2) relay outputs end of starting relay NO(R3) relay outputs motor powered NO output absolute accuracy precision +/- 5 % minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms discrete input number 5 discrete input type PTC, 750 Ohm at 25 °C(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm discrete input voltage 24 V <= 30 V discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA starting current 0.4...1.3 Icl adjustable analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm communication port protocol Modbus connector type 1 RJ45 communication data link Serial physical interface RS485 multidrop transmission rate 4800, 9600 or 19200 bps max nodes number 31 protection type Phase failure: lineThermal protection: motorThermal protection: starter marking CE operating position Vertical +/- 10 degree height 890 mm width 770 mm depth 315 mm net weight 115 kg Motor power range AC-3 250…500 kW at 200…240 V 3 phases560…900 kW at 380…440 V 3 phases560…900 kW at 480…500 V 3 phases motor starter type Soft starter