Three-Phase – 200-480 V
SKU: bc-648
$316.00
Currently out of stock — contact us for lead times
Description
Main - ATSU01N206LT range of product Altistart U01 and TeSys U product or component type Soft starter product destination Asynchronous motors product specific application Simple machine device short name ATSU01 network number of phases 3 phases [Us] rated supply voltage 200...480 V - 10...10 % motor power kW 3 kW, 3 phases at 400 V0.75 kW, 3 phases at 230 V2.2 kW, 3 phases at 400 V1 kW, 3 phases at 230 V1.5 kW, 3 phases at 400 V motor power hp 1 hp, 3 phases at 230 V2 hp, 3 phases at 460 V3 hp, 3 phases at 460 V1.5 hp, 3 phases at 230 V IcL starter rating 6 A utilisation category AC-53B conforming to EN/IEC 60947-4-2 current consumption 65 mA type of start Start with voltage ramp power dissipation in W 1.5 W at full load and at end of starting61.5 W in transient state Complementary assembly style With heat sink function available Integrated bypass supply voltage limits 180…528 V supply frequency 50...60 Hz - 5...5 % network frequency 47.5...63 Hz output voltage <= power supply voltage [Uc] control circuit voltage 24 V DC +/- 10 % starting time 1 s / 1005 s / 2010 s / 10Adjustable from 1 to 10 s deceleration time symb Adjustable from 1 to 10 s starting torque 30...80 % of starting torque of motor connected directly on the line supply discrete input type Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm discrete input voltage 24...40 V input output isolation Galvanic between power and control discrete input logic Positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA discrete output current 2 A DC-133 A AC-15 discrete output type Open collector logic LO1 end of starting signalRelay outputs R1A, R1C NO discrete output voltage 24 V (voltage limits: 6...30 V) open collector logic minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive loadRelay outputs: 2 A at 250 V AC AC-15 cos phi = 0.5 and L/R = 20 ms inductive load maximum switching voltage 440 V relay outputs display type 1 LED (green) for starter powered up1 LED (yellow) for nominal voltage reached tightening torque 1.9…2.5 N.m0.5 N.m electrical connection 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuitScrew connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuitScrew connector - rigid 2 0.5...1 mm² AWG 17 control circuitScrew connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuitScrew connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuitScrew connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit marking CE operating position Vertical +/- 10 degree height 234 mm width 45 mm depth 150 mm net weight 0.34 kg Motor power range AC-3 0.55…1 kW at 200…240 V 3 phases1.1…2 kW at 380…440 V 3 phases2.2…3 kW motor starter type Soft starter Main - ATSU01N209LT range of product Altistart U01 and TeSys U product or component type Soft starter product destination Asynchronous motors product specific application Simple machine device short name ATSU01 network number of phases 3 phases [Us] rated supply voltage 200...480 V - 10...10 % motor power kW 4 kW, 3 phases at 400 V1.5 kW, 3 phases at 230 V motor power hp 2 hp, 3 phases at 230 V5 hp, 3 phases at 460 V IcL starter rating 9 A utilisation category AC-53B conforming to EN/IEC 60947-4-2 current consumption 65 mA type of start Start with voltage ramp power dissipation in W 1.5 W at full load and at end of starting91.5 W in transient state Complementary assembly style With heat sink function available Integrated bypass supply voltage limits 180…528 V supply frequency 50...60 Hz - 5...5 % network frequency 47.5...63 Hz output voltage <= power supply voltage [Uc] control circuit voltage 24 V DC +/- 10 % starting time 1 s / 1005 s / 2010 s / 10Adjustable from 1 to 10 s deceleration time symb Adjustable from 1 to 10 s starting torque 30...80 % of starting torque of motor connected directly on the line supply discrete input type Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm discrete input voltage 24...40 V input output isolation Galvanic between power and control discrete input logic Positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA discrete output current 2 A DC-133 A AC-15 discrete output type Open collector logic LO1 end of starting signalRelay outputs R1A, R1C NO discrete output voltage 24 V (voltage limits: 6...30 V) open collector logic minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive loadRelay outputs: 2 A at 250 V AC AC-15 cos phi = 0.5 and L/R = 20 ms inductive load maximum switching voltage 440 V relay outputs display type 1 LED (green) for starter powered up1 LED (yellow) for nominal voltage reached tightening torque 0.5 N.m1.9…2.5 N.m electrical connection 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuitScrew connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuitScrew connector - rigid 2 0.5...1 mm² AWG 17 control circuitScrew connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuitScrew connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuitScrew connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit marking CE operating position Vertical +/- 10 degree height 234 mm width 45 mm depth 150 mm net weight 0.34 kg Motor power range AC-3 1.1…2 kW at 200…240 V 3 phases2.2…3 kW at 380…440 V 3 phases4…6 kW motor starter type Soft starter Main - ATSU01N212LT range of product Altistart U01 and TeSys U product or component type Soft starter product destination Asynchronous motors product specific application Simple machine device short name ATSU01 network number of phases 3 phases [Us] rated supply voltage 200...480 V - 10...10 % motor power kW 2.2 kW, 3 phases at 230 V5.5 kW, 3 phases at 400 V3 kW, 3 phases at 230 V motor power hp 3 hp, 3 phases at 230 V7.5 hp, 3 phases at 460 V IcL starter rating 12 A utilisation category AC-53B conforming to EN/IEC 60947-4-2 current consumption 65 mA type of start Start with voltage ramp power dissipation in W 1.5 W at full load and at end of starting121.5 W in transient state Complementary assembly style With heat sink function available Integrated bypass supply voltage limits 180…528 V supply frequency 50...60 Hz - 5...5 % network frequency 47.5...63 Hz output voltage <= power supply voltage [Uc] control circuit voltage 24 V DC +/- 10 % starting time 1 s / 1005 s / 2010 s / 10Adjustable from 1 to 10 s deceleration time symb Adjustable from 1 to 10 s starting torque 30...80 % of starting torque of motor connected directly on the line supply discrete input type Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm discrete input voltage 24...40 V input output isolation Galvanic between power and control discrete input logic Positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA discrete output current 2 A DC-133 A AC-15 discrete output type Open collector logic LO1 end of starting signalRelay outputs R1A, R1C NO discrete output voltage 24 V (voltage limits: 6...30 V) open collector logic minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive loadRelay outputs: 2 A at 250 V AC AC-15 cos phi = 0.5 and L/R = 20 ms inductive load maximum switching voltage 440 V relay outputs display type 1 LED (green) for starter powered up1 LED (yellow) for nominal voltage reached tightening torque 1.9…2.5 N.m0.5 N.m electrical connection 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuitScrew connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuitScrew connector - rigid 2 0.5...1 mm² AWG 17 control circuitScrew connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuitScrew connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuitScrew connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit marking CE operating position Vertical +/- 10 degree height 234 mm width 45 mm depth 150 mm net weight 0.34 kg Motor power range AC-3 2.2…3 kW at 200…240 V 3 phases4…6 kW at 380…440 V 3 phases motor starter type Soft starter Main - ATSU01N222LT range of product Altistart U01 and TeSys U product or component type Soft starter product destination Asynchronous motors product specific application Simple machine device short name ATSU01 network number of phases 3 phases [Us] rated supply voltage 200...480 V - 10...10 % motor power kW 11 kW, 3 phases at 400 V4 kW, 3 phases at 230 V7.5 kW, 3 phases at 400 V5.5 kW, 3 phases at 230 V motor power hp 5 hp, 3 phases at 230 V7.5 hp, 3 phases at 230 V10 hp, 3 phases at 460 V15 hp, 3 phases at 460 V IcL starter rating 22 A utilisation category AC-53B conforming to EN/IEC 60947-4-2 current consumption 100 mA type of start Start with voltage ramp power dissipation in W 2.5 W at full load and at end of starting222.5 W in transient state Complementary assembly style With heat sink function available Integrated bypass supply voltage limits 180…528 V supply frequency 50...60 Hz - 5...5 % network frequency 47.5...63 Hz output voltage <= power supply voltage [Uc] control circuit voltage 24 V DC +/- 10 % starting time 1 s / 1005 s / 2010 s / 10Adjustable from 1 to 10 s deceleration time symb Adjustable from 1 to 10 s starting torque 30...80 % of starting torque of motor connected directly on the line supply discrete input type Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm discrete input voltage 24...40 V input output isolation Galvanic between power and control discrete input logic Positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA discrete output current 2 A DC-133 A AC-15 discrete output type Open collector logic LO1 end of starting signalRelay outputs R1A, R1C NO discrete output voltage 24 V (voltage limits: 6...30 V) open collector logic minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive loadRelay outputs: 2 A at 250 V AC AC-15 cos phi = 0.5 and L/R = 20 ms inductive load maximum switching voltage 440 V relay outputs display type 1 LED (green) for starter powered up1 LED (yellow) for nominal voltage reached tightening torque 1.9…2.5 N.m0.5 N.m electrical connection 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuitScrew connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuitScrew connector - rigid 2 0.5...1 mm² AWG 17 control circuitScrew connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuitScrew connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuitScrew connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit marking CE operating position Vertical +/- 10 degree height 314 mm width 45 mm depth 170 mm net weight 0.49 kg Motor power range AC-3 4…6 kW at 200…240 V 3 phases7…11 kW at 380…440 V 3 phases motor starter type Soft starter Main - ATSU01N232LT range of product Altistart U01 and TeSys U product or component type Soft starter product destination Asynchronous motors product specific application Simple machine device short name ATSU01 network number of phases 3 phases [Us] rated supply voltage 200...480 V - 10...10 % motor power kW 15 kW, 3 phases at 400 V7.5 kW, 3 phases at 230 V motor power hp 10 hp, 3 phases at 230 V20 hp, 3 phases at 460 V IcL starter rating 32 A utilisation category AC-53B conforming to EN/IEC 60947-4-2 current consumption 100 mA type of start Start with voltage ramp power dissipation in W 2.5 W at full load and at end of starting322.5 W in transient state Complementary assembly style With heat sink function available Integrated bypass supply voltage limits 180…528 V supply frequency 50...60 Hz - 5...5 % network frequency 47.5...63 Hz output voltage <= power supply voltage [Uc] control circuit voltage 24 V DC +/- 10 % starting time Adjustable from 1 to 10 s1 s / 5010 s / 55 s / 10 deceleration time symb Adjustable from 1 to 10 s starting torque 30...80 % of starting torque of motor connected directly on the line supply discrete input type Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm discrete input voltage 24...40 V input output isolation Galvanic between power and control discrete input logic Positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA discrete output current 2 A DC-133 A AC-15 discrete output type Open collector logic LO1 end of starting signalRelay outputs R1A, R1C NO discrete output voltage 24 V (voltage limits: 6...30 V) open collector logic minimum switching current 10 mA at 6 V DC for relay outputs maximum switching current Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive loadRelay outputs: 2 A at 250 V AC AC-15 cos phi = 0.5 and L/R = 20 ms inductive load maximum switching voltage 440 V relay outputs display type 1 LED (green) for starter powered up1 LED (yellow) for nominal voltage reached tightening torque 1.9…2.5 N.m0.5 N.m electrical connection 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuitScrew connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuitScrew connector - rigid 2 0.5...1 mm² AWG 17 control circuitScrew connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuitScrew connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuitScrew connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit marking CE operating position Vertical +/- 10 degree height 314 mm width 45 mm depth 170 mm net weight 0.49 kg Motor power range AC-3 7…11 kW at 200…240 V 3 phases15…25 kW at 380…440 V 3 phases motor starter type Soft starter