Options for Customisation in Field
SKU: bc-655
$169.85
Currently out of stock — contact us for lead times
Description
Main - RM22TR33 range of product Harmony Control Relays product or component type 3-phase control relay relay type Control relay network number of phases 3 phases relay name RM22TR relay monitored parameters Overvoltage and undervoltage detectionPhase sequencePhase failure detection time delay type Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt switching capacity in VA 2000 VA measurement range 380...480 V voltage AC contacts type and composition 2 C/O Complementary reset time 1500 ms at maximum voltage maximum switching voltage 250 V AC minimum switching current 10 mA at 5 V DC maximum switching current 8 A AC [Us] rated supply voltage 380...480 V AC supply voltage limits 304…576 V AC operating limits - 20 % + 20 % Un power consumption in VA 15 VA at 480 V AC 60 Hz voltage detection threshold < 100 V AC supply voltage frequency 50...60 Hz +/- 10 % output contacts 2 C/O nominal output current 8 A setting accuracy of the switching threshold +/- 10 % of the full scale switching threshold drift <= 0.05 % per degree centigrade depending permissible ambient air temperature<= 1 % within the supply voltage range setting accuracy of time delay 10 P time delay drift <= 0.05 % per degree centigrade depending permissible ambient air temperature<= 1 % within the supply voltage range hysteresis 2 % fixed of selectable run-up delay at power-up 650 ms maximum measuring cycle 150 ms measurement cycle as true rms value threshold adjustment voltage 2...20 % of Un selected voltage range 380...480 V phase to phase repeat accuracy +/- 0.5 % for input and measurement circuit+/- 3 % for time delay measurement error < 1 % over the whole range with voltage variation< 0.05 %/°C with temperature variation response time <= 300 ms overvoltage category III conforming to IEC 60664-1III conforming to UL 508 insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27 mounting position Any position connections - terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable endScrew terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable endScrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable endScrew terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end tightening torque 0.6…1 N.m conforming to IEC 60947-1 housing material Self-extinguishing plastic status LED LED (yellow)relay ONLED (green)power ON mounting support 35 mm DIN rail conforming to EN/IEC 60715 electrical durability 100000 cycles mechanical durability 10000000 cycles utilisation category AC-15 conforming to IEC 60947-5-1DC-13 conforming to IEC 60947-5-1AC-1 conforming to IEC 60947-4-1DC-1 conforming to IEC 60947-4-1 safety reliability data MTTFd = 388.1 yearsB10d = 350000 contacts material Cadmium free width 22.5 mm net weight 0.09 kg Main - LT3SM00M range of product LT3 device short name LT3SM product or component type Thermistor protection units [Uc] control circuit voltage 115...230 V AC 50/60 Hz reset Manual Complementary control circuit voltage limits 0.85...1.1 Uc contacts type and composition 1 NC + 1 NO dual voltage [Ith] conventional free air thermal current 5 A for output control relay [Ui] rated insulation voltage Output control relay: 500 V AC [Ue] rated operational voltage 250 V AC 50/60 Hz for output control relay signalling function Fault indicationVoltage indication control type Manual testManual reset probe interchangeability Label mark A conforming to IEC 60034-11 hold-in power consumption in W 1 W hold-in power consumption in VA 2.5 VA resistance 1500…1650 Ohm reset2700…3100 Ohm tripping number of probes 0…6 input voltage < 2.5 V (1500 Ohm) for probe< 7.5 V (4000 Ohm) for probe conforming to IEC 60034-11 maximum short circuit detection resistance 20 Ohm condition of use Connection of probes 1000 m >2.5 mm²Connection of probes 500 m >1.5 mm² [Uimp] rated impulse withstand voltage 2.5 kV rated power in VA 100 VA at 220 V - electrical durability: 500000 cycles breaking capacity 2 A at 24 V DC DC-133 A at 250 V AC AC-166 A at 120 V AC AC-16 connections - terminals Power circuit: cage type connector 1 cable(s) 0.75…2.5 mm²flexible with cable endPower circuit: cage type connector 1 cable(s) 0.75…2.5 mm²solid with cable endPower circuit: cage type connector 1 cable(s) 1…2.5 mm²flexible without cable endPower circuit: cage type connector 1 cable(s) 1…2.5 mm²solid without cable endPower circuit: cage type connector 2 cable(s) 0.75…2.5 mm²flexible with cable endPower circuit: cage type connector 2 cable(s) 0.75…2.5 mm²solid with cable endPower circuit: cage type connector 2 cable(s) 1…2.5 mm²flexible without cable endPower circuit: cage type connector 2 cable(s) 1…2.5 mm²solid without cable end tightening torque 0.8 N.m height 100 mm width 22.5 mm depth 100 mm net weight 0.22 kg Main - RE22R1MYMR range of product Harmony Timer Relays product or component type Multifunction relay discrete output type Relay device short name RE22 nominal output current 8 A Complementary contacts type and composition 1 C/O timed contact, cadmium free time delay type Power on-delayOff-delayOn-delay and off-delaySymmetrical flashingInterval time delay range 30...300 s10...100 s3...30 s30...300 min3...30 min0.3...3 s0.05...1 s30...300 h1...10 s3...30 h control type Rotary knobDiagnostic buttonPotentiometer external [Us] rated supply voltage 24...240 V AC/DC 50/60 Hz Release input voltage <= 2.4 V voltage range 0.85...1.1 Us supply frequency 50...60 Hz +/- 5 % connections - terminals Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable endScrew terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable endScrew terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable endScrew terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end tightening torque 0.6…1 N.m conforming to IEC 60947-1 housing material Self-extinguishing repeat accuracy +/- 0.5 % conforming to IEC 61812-1 temperature drift +/- 0.05 %/°C voltage drift +/- 0.2 %/V setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 Control signal pulse width 100 ms with load in parallel30 ms insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1 Recovery time 120 ms on de-energisation immunity to microbreaks 10 ms power consumption in VA 3 VA at 240 V AC power consumption in W 1.5 W at 240 V DC switching capacity in VA 2000 VA minimum switching current 10 mA at 5 V DC maximum switching current 8 A maximum switching voltage 250 V AC electrical durability 100000 cycles, 8 A at 250 V, AC-1100000 cycles, 2 A at 24 V, DC-1 mechanical durability 10000000 cycles Rated impulse withstand voltage 5 kV for 1.2…50 µs conforming to IEC 60664-1 Power on delay 100 ms creepage distance 4 kV/3 conforming to IEC 60664-1 overvoltage category III conforming to IEC 60664-1 safety reliability data MTTFd = 205.4 yearsB10d = 190000 mounting position Any position mounting support 35 mm DIN rail conforming to EN/IEC 60715 status LED LED backlight green (steady) for dial pointer indicationLED yellow (steady) for output relay energisedLED yellow (fast flashing) for timing in progress and output relay de-energisedLED yellow (slow flashing) for timing in progress and output relay energised width 22.5 mm net weight 0.1 kg Main RSB2A080P7 range of product Harmony Electromechanical Relays series name Interface relay product or component type Plug-in relay device short name RSB contacts type and composition 2 C/O contact operation Standard [Uc] control circuit voltage 230 V AC 50/60 Hz [Ithe] conventional enclosed thermal current 8 A at -40…40 °C status LED Without control type Without push-button Complementary shape of pin Flat (PCB type) average coil resistance 33000 Ohm network: AC at 20 °C +/- 10 % [Ue] rated operational voltage 184...345 V AC 50/60 Hz [Ui] rated insulation voltage 400 V conforming to EN/IEC 60947 [Uimp] rated impulse withstand voltage 3.6 kV conforming to IEC 61000-4-5 contacts material Silver alloy (AgNi) [Ie] rated operational current 4 A (AC-1/DC-1) NC conforming to IEC8 A (AC-1/DC-1) NO conforming to IEC minimum switching current 10 mA maximum switching voltage 300 V DC conforming to IEC minimum switching voltage 12 V maximum switching capacity 2000 VA/224 W resistive rated load 8 A at 250 V AC8 A at 28 V DC minimum switching capacity 120 mW at 10 mA, 12 V operating rate <= 600 cycles/hour under load<= 18000 cycles/hour no-load mechanical durability 5000000 cycles electrical durability 100000 cycles, 8 A at 250 V, AC-1 NO100000 cycles, 4 A at 250 V, AC-1 NC operating time 20 ms operating20 ms reset average coil consumption 0.75 VA AC drop-out voltage threshold >= 0.15 Uc AC safety reliability data B10d = 100000 protection category RT I test levels Level A group mounting operating position Any position net weight 0.014 kg sale per indivisible quantity 10 device presentation Complete product Main - RSZE1S48M range of product Harmony Electromechanical Relays product or component type Socket contact terminal arrangement Separate product compatibility Plug-in relay RSB with 1 C/O contactPlug-in relay RSB with 2 C/O contact shape of pin Flat device short name RSZ sale per indivisible quantity 10 Complementary [Ith] conventional free air thermal current 10 A [Ue] rated operational voltage < 250 V AC tightening torque < 0.8 N.m for M3 screw(s) fixing mode By screw (panel)Clip-on (35 mm symmetrical DIN rail) marking CE width 15.5 mm net weight 0.05 kg Main - ZB4BD3 range of product Harmony XB4 product or component type Head for selector switch device short name ZB4 bezel material Chromium plated metal mounting diameter 22 mm head type Standard sale per indivisible quantity 1 shape of signaling unit head Round type of operator stay put operator profile Black standard handle operator position information 3 positions +/- 45° Complementary CAD overall width 29 mm CAD overall height 29 mm CAD overall depth 44 mm net weight 0.04 kg resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m mechanical durability 1000000 cycles electrical composition code C3 for <6 contacts using single blocks in front mountingC4 for <6 contacts using single and double blocks in front mountingC5 for <5 contacts using single blocks in front mountingC6 for <5 contacts using single and double blocks in front mountingC7 for <4 contacts using single blocks in front mountingC8 for <4 contacts using single and double blocks in front mountingC11 for <3 contacts using single blocks in front mounting device presentation Basic element Main - ZB4BZ103 range of product Harmony XB4 product or component type Complete body/contact assembly device short name ZB4 fixing collar material Zamak sale per indivisible quantity 1 head type Standard contacts type and composition 2 NO contact operation Slow-break contact block type Single device composition BodyFixing collar connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1 Complementary CAD overall width 30 mm CAD overall height 47 mm CAD overall depth 37 mm terminals description ISO n°1 (13-14)NO net weight 0.062 kg contacts usage Standard contacts positive opening Without operating travel 2.6 mm (NO changing electrical state)4.3 mm (total travel) operating torque 0.05 N.m NO changing electrical state mechanical durability 5000000 cycles tightening torque 0.8…1.2 N.m conforming to EN 60947-1 shape of screw head Cross compatible with Philips no 1 screwdriverCross compatible with pozidriv No 1 screwdriverSlotted compatible with flat Ø 4 mm screwdriverSlotted compatible with flat Ø 5.5 mm screwdriver contacts material Silver alloy (Ag/Ni) short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 [Ith] conventional free air thermal current 10 A conforming to EN/IEC 60947-5-1 [Ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN 60947-1 [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-1 [Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-16 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-10.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-10.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-10.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-11.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 electrical durability 10000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C10000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C10000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C10000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C10000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C electrical reliability Λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4 device presentation Basic sub-assemblies Main - ZBY2385M product or component type Legend holder accessory / separate part category Marking accessory Complementary device composition Legend holderMarked legend accessory / separate part destination Ø 22 mm control or signalling unit range compatibility Harmony XB4Harmony XB5 legend holder size 30 x 40 mm marking White AUTO-O-MAN on 1 black side, 1 red side background user language English net weight 0.002 kg Main - RSB1A160P7 range of product Harmony Electromechanical Relays series name Interface relay product or component type Plug-in relay device short name RSB contacts type and composition 1 C/O contact operation Standard [Uc] control circuit voltage 230 V AC 50/60 Hz [Ithe] conventional enclosed thermal current 16 A at -40…40 °C status LED Without control type Without push-button Complementary shape of pin Flat (PCB type) average coil resistance 33000 Ohm network: AC at 20 °C +/- 10 % [Ue] rated operational voltage 184...345 V AC 50/60 Hz [Ui] rated insulation voltage 400 V conforming to EN/IEC 60947 [Uimp] rated impulse withstand voltage 3.6 kV conforming to IEC 61000-4-5 contacts material Silver alloy (AgNi) [Ie] rated operational current 16 A (AC-1/DC-1) NO conforming to IEC8 A (AC-1/DC-1) NC conforming to IEC minimum switching current 10 mA maximum switching voltage 300 V DC conforming to IEC minimum switching voltage 12 V maximum switching capacity 4000 VA/448 W resistive rated load 16 A at 250 V AC16 A at 28 V DC minimum switching capacity 120 mW at 10 mA, 12 V operating rate <= 600 cycles/hour under load<= 18000 cycles/hour no-load mechanical durability 10000000 cycles electrical durability 100000 cycles, 16 A at 250 V, AC-1 NO100000 cycles, 8 A at 250 V, AC-1 NC operating time 20 ms operating20 ms reset average coil consumption 0.75 VA AC drop-out voltage threshold >= 0.15 Uc AC safety reliability data B10d = 100000 protection category RT I test levels Level A group mounting operating position Any position net weight 0.014 kg sale per indivisible quantity 10 device presentation Complete product Main - ZMLB010A2S12 range of product OsiSense XM product or component type Electromechanical pressure sensor pressure sensor type Electromechanical pressure sensor device short name XMLB pressure rating 10 bar controlled fluid Air (0…70 °C)Fresh water (0…70 °C)Hydraulic oil (0…70 °C) fluid connection type G 1/4 (female) conforming to ISO 228 electrical connection Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²1 connector ISO M20 AWG gauge AWG 20...AWG 14 cable entry Cable gland 7…13 mm contacts type and composition 1 C/O product specific application - pressure switch type of operation Regulation between 2 thresholds electrical circuit type Control circuit scale type Adjustable differential local display With adjustable range of switching point on rising pressure 0.7…10 bar adjustable range of switching point on falling pressure 0.13…9.15 bar possible differential maximum at high setting 7.5 bar maximum permissible accidental pressure 22.5 bar destruction pressure 45 bar pressure actuator Diaphragm materials in contact with fluid Zinc alloyFPM, FKM enclosure material Zinc alloy [In] rated current 3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-11.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-10.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1 Complementary possible differential minimum at low setting 0.57 bar (+/- 0.05 bar) possible differential minimum at high setting 0.85 bar (- 0.1 bar, + 0.15 bar) maximum permissible pressure - per cycle 12.5 bar terminal block type 4 terminals maximum operating rate 120 cyc/mn repeat accuracy 2 % [Ui] rated insulation voltage 300 V conforming to UL 508500 V conforming to EN/IEC 60947-1300 V conforming to CSA C22.2 No 14 [Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-1 auxiliary contacts operation Snap action contacts material Silver contacts maximum resistance across terminals 25 mOhm conforming to IEC 255-7 category 325 mOhm conforming to NF C 93-050 method A short-circuit protection 10 A cartridge fuse, type gG (gl) mechanical durability 5000000 cycles setting External height 113 mm depth 75 mm width 35 mm net weight 0.705 kg