NSX100.160.250 NA
SKU: bc-618
$252.39
Currently out of stock — contact us for lead times
Description
Main - LV429629 Range Compact Product Name ComPact NSX100 Product or Component Switch Disconnector Device short Name Compact NSX100NA Poles Description 3P Network Type AC, DC [Ue] Rated Operational Voltage 90 V AC 50/60 Hz conforming to IEC 60947-3 750 V DC 3 poles in series conforming to IEC 60947-3 500 V DC 2 poles in series conforming to IEC 60947-3 250 V DC 1 pole conforming to IEC 60947-3 [le] Rate Operational Current AC-22A: 100 A AC 50/60 Hz 220...690 V AC-23A: 100 A AC 50/60 Hz 220...690 V DC-22A: 100 A DC 250 V 1 pole DC-22A: 100 A DC 500 V 2 poles in series DC-23A: 100 A DC 250 V 1 pole DC-23A: 100 A DC 500 V 2 poles in series [Ui] Rated Insulation Voltage 800 V AC 50/60 Hz conforming to IEC 60947-3 [Uimp] Rated Impulse withstand Voltage 8 kV Conforming to IEC 60947-3 [lth] Conventional Free Air Thermal Current 100 A at 60°C [Icm] Rated Short-Circuit Making Current 330 KA with upstream protection circuit breaker 2.6 kA switch-disconnector alone Breaking Capacity Code NA Suitability for Isolation Yes conforming to EN 60947-3 Yes conforming to IEC 60947-3 Contact Position Indicator Yes Visible Break No Pollution Degree 3 Conforming to IEC 60664-1 Complementary Cotrol Type Toggle Mounting Mode Fixed Mounting Support Backplate Upside Connection Front Downside Connection Front [Icw] Rated Short-Time Withstand Current 0.69 KA during 20 s conforming to IEC 60947-3 1.8 KA during 1 s conforming to IEC 60947-3 1.8 kA during 3 s conforming to IEC 60947-3 Mechanical Durability 50000 Cycles Conforming to IEC 60947-3 Electrical Durability AC-22A: 10000 cycles 250 V DC In/2 (1 pole) conforming to IEC 60947-3 AC-22A: 15000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-22A: 20000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-3 AC-22A: 35000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-22A: 5000 cycles 500 V DC In (2 poles in series) conforming to IEC 60947-3 AC-22A: 8000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-3 AC-23A: 10000 cycles 250 V DC In/2 (1 pole) conforming to IEC 60947-3 AC-23A: 15000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-23A: 20000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-3 AC-23A: 35000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-23A: 5000 cycles 500 V DC In (2 poles in series) conforming to IEC 60947-3 AC-23A: 8000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-3 Connection pitch 35mm Width (W) 105mm Height (H) 161mm Depth (D) 86mm Product Weight 1.8kg Main - LV430629 Range Compact Product Name ComPact NSX100 Product or Component Switch Disconnector Device short Name Compact NSX100NA Poles Description 3P Network Type DC, AC [Ue] Rated Operational Voltage 690 V AC 50/60 Hz conforming to IEC 60947-3 750 V DC 3 poles in series conforming to IEC 60947-3 500 V DC 2 poles in series conforming to IEC 60947-3 250 V DC 1 pole conforming to IEC 60947-3 [le] Rate Operational Current AC-22A: 160 A AC 50/60 Hz 220...690 V AC-23A: 160 A AC 50/60 Hz 220...690 V DC-22A: 160 A DC 250 V 1 pole DC-22A: 160 A DC 500 V 2 poles in series DC-23A: 160 A DC 250 V 1 pole DC-23A: 160 A DC 500 V 2 poles in series [Ui] Rated Insulation Voltage 800 V AC 50/60 Hz conforming to IEC 60947-3 [Uimp] Rated Impulse withstand Voltage 8 kV Conforming to IEC 60947-3 [lth] Conventional Free Air Thermal Current 160 A at 60°C [Icm] Rated Short-Circuit Making Current 330 KA with upstream protection circuit breaker 3.6 kA switch-disconnector alone Breaking Capacity Code NA Suitability for Isolation Yes conforming to EN 60947-3 Yes conforming to IEC 60947-3 Contact Position Indicator Yes Visible Break No Pollution Degree 3 Conforming to IEC 60664-1 Complementary Cotrol Type Toggle Mounting Mode Fixed Mounting Support Backplate Upside Connection Front Downside Connection Front [Icw] Rated Short-Time Withstand Current 0.96 KA during 20 s conforming to IEC 60947-3 2.5 KA during 1 s conforming to IEC 60947-3 2.5 kA during 3 s conforming to IEC 60947-3 Mechanical Durability 40000 Cycles Conforming to IEC 60947-3 Electrical Durability AC-22A: 10000 cycles 250 V DC In/2 (1 pole) conforming to IEC 60947-3 AC-22A: 5000 cycles 500 V DC In (2 poles in series) conforming to IEC 60947-3 AC-23A: 10000 cycles 250 V DC In/2 (1 pole) conforming to IEC 60947-3 AC-23A: 5000 cycles 500 V DC In (2 poles in series) conforming to IEC 60947-3 AC-22A: 10000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-22A: 15000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-3 AC-22A: 30000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-22A: 5000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-3 AC-23A: 10000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-23A: 15000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-3 AC-23A: 30000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-23A: 5000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-3 Connection pitch 35mm Width (W) 105mm Height (H) 161mm Depth (D) 86mm Product Weight 1.8kg Main - LV431629 Range Compact Product Name ComPact NSX100 Product or Component Switch Disconnector Device short Name Compact NSX100NA Poles Description 3P Network Type AC, DC [Ue] Rated Operational Voltage 690 V AC 50/60 Hz conforming to IEC 60947-3 750 V DC 3 poles in series conforming to IEC 60947-3 500 V DC 2 poles in series conforming to IEC 60947-3 250 V DC 1 pole conforming to IEC 60947-3 [le] Rate Operational Current AC-22A: 250 A AC 50/60 Hz 220...690 V AC-23A: 250 A AC 50/60 Hz 220...690 V DC-22A: 250 A DC 250 V 1 pole DC-22A: 250 A DC 500 V 2 poles in series DC-23A: 250 A DC 250 V 1 pole DC-23A: 250 A DC 500 V 2 poles in series [Ui] Rated Insulation Voltage 800 V AC 50/60 Hz conforming to IEC 60947-3 [Uimp] Rated Impulse withstand Voltage 8 kV Conforming to IEC 60947-3 [lth] Conventional Free Air Thermal Current 250A at 60°C [Icm] Rated Short-Circuit Making Current 330 KA with upstream protection circuit breaker 4.9 kA switch-disconnector alone Breaking Capacity Code NA Suitability for Isolation Yes conforming to EN 60947-3 Yes conforming to IEC 60947-3 Contact Position Indicator Yes Visible Break No Pollution Degree 3 Conforming to IEC 60664-1 Complementary Cotrol Type Toggle Mounting Mode Fixed Mounting Support Backplate Upside Connection Front Downside Connection Front [Icw] Rated Short-Time Withstand Current 1.35 KA during 20 s conforming to IEC 60947-3 3.5 KA during 1 s conforming to IEC 60947-3 3.5 kA during 3 s conforming to IEC 60947-3 Mechanical Durability 20000 Cycles Conforming to IEC 60947-3 Electrical Durability AC-22A: 10000 cycles 250 V DC In/2 (1 pole) conforming to IEC 60947-3 AC-22A: 5000 cycles 500 V DC In (2 poles in series) conforming to IEC 60947-3 AC-23A: 10000 cycles 250 V DC In/2 (1 pole) conforming to IEC 60947-3 AC-23A: 5000 cycles 500 V DC In (2 poles in series) conforming to IEC 60947-3 AC-22A: 15000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-22A: 3000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-3 AC-22A: 60000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-22A: 7500 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-3 AC-23A: 15000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-23A: 3000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-3 AC-23A: 60000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-3 AC-23A: 7500 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-3 Connection pitch 35mm Width (W) 105mm Height (H) 161mm Depth (D) 86mm Product Weight 1.8kg