NSX 400.630H
SKU: bc-623
$1,326.46
Currently out of stock — contact us for lead times
Description
Main - LV432709 range ComPact product name ComPact NSX range of product ComPact NSX400...630 device short name NSX400H product or component type Circuit breaker device application Distribution Number of poles 3P protected poles description 3t [In] rated current 250 A at 40 °C [Ue] rated operational voltage 690 V AC 50/60 Hz network type AC network frequency 50/60 Hz suitability for isolation Yes conforming to EN/IEC 60947-2 utilisation category Category A [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50865 kA at 480 V AC 50/60 Hz conforming to UL 508100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-265 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-220 kA at 600 V AC 50/60 Hz conforming to UL 50820 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 Performance level H 70 kA 415 V AC trip unit name Micrologic 2.3 trip unit technology Electronic trip unit protection functions LSoI control type Toggle Circuit breaker mounting mode Fixed Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 8 kV [Ics] rated service short-circuit breaking capacity 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-210 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-250 kA at 500 V AC 50/60 Hz conforming to IEC 60947-265 kA at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 mechanical durability 15000 cycles electrical durability 3000 cycles at 690 V In6000 cycles at 690 V In/26000 cycles at 440 V In12000 cycles at 440 V In/2 mounting support Backplate upside connection Front downside connection Front connection pitch 45 mm protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection trip unit rating 250 A at 40 °C Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings [Ir] long-time protection pick-up adjustment range 70...250 A Long-time protection delay adjustment type tr Fixed [tr] long-time protection delay adjustment range 16 s at 6 x Ir thermal memory 20 minutes before and after tripping Short-time protection pick-up adjustment type Isd Adjustable 9 settings [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir Short-time protection delay adjustment type tsd Fixed Instantaneous protection pick-up adjustment type Ii Fixed [Ii] instantaneous protection pick-up adjustment range 3000 A earth-leakage protection Without zone selective interlocking ZSI Without Number of slots for electrical auxiliaries 6 slot(s) local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload Width (W) 140 mm Height (H) 255 mm Depth (D) 110 mm net weight 6.05 kg Main - LV432895 range ComPact product name ComPact NSX range of product ComPact NSX400...630 device short name NSX630H product or component type Circuit breaker device application Distribution Number of poles 3P protected poles description 3t [In] rated current 630 A at 40 °C [Ue] rated operational voltage 690 V AC 50/60 Hz network type AC network frequency 50/60 Hz suitability for isolation Yes conforming to EN/IEC 60947-2 utilisation category Category A [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50865 kA at 480 V AC 50/60 Hz conforming to UL 508100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-265 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-220 kA at 600 V AC 50/60 Hz conforming to UL 50820 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 Performance level H 70 kA 415 V AC trip unit name Micrologic 2.3 trip unit technology Electronic trip unit protection functions LSoI control type Toggle Circuit breaker mounting mode Fixed Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 8 kV [Ics] rated service short-circuit breaking capacity 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-210 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-250 kA at 500 V AC 50/60 Hz conforming to IEC 60947-265 kA at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 mechanical durability 15000 cycles electrical durability 2000 cycles at 690 V In6000 cycles at 690 V In/24000 cycles at 440 V In8000 cycles at 440 V In/2 mounting support Backplate upside connection Front downside connection Front connection pitch 45 mm protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection trip unit rating 630 A at 40 °C Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings [Ir] long-time protection pick-up adjustment range 250...630 A Long-time protection delay adjustment type tr Fixed [tr] long-time protection delay adjustment range 16 s at 6 x Ir thermal memory 20 minutes before and after tripping Short-time protection pick-up adjustment type Isd Adjustable 9 settings [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir Short-time protection delay adjustment type tsd Fixed Instantaneous protection pick-up adjustment type Ii Fixed [Ii] instantaneous protection pick-up adjustment range 6900 A earth-leakage protection Without zone selective interlocking ZSI Without Number of slots for electrical auxiliaries 6 slot(s) local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload Width (W) 140 mm Height (H) 255 mm Depth (D) 110 mm net weight 6.2 kg