AJ&LI Enterprise
LV431861

NSX 100.160.250F (Distribution & Motor)

SKU: bc-616

$257.43

Currently out of stock — contact us for lead times

Ask a Question

Description

Main - LV429637 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX100F   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 16 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 50825 kA at 480 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50822 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   Performance level F 36 kA 415 V AC   trip unit name TM-D   trip unit technology Thermal-magnetic   trip unit protection functions LI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-235 kA at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-24 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 50000 cycles   electrical durability 10000 cycles at 690 V In20000 cycles at 690 V In/230000 cycles at 440 V In50000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (thermal)I : for short-circuit protection (magnetic)   trip unit rating 16 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable   [Ir] long-time protection pick-up adjustment range 0.7...1 x In   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 120…400 s at 1.5 x In15 s at 6 x Ir   Short-time protection pick-up adjustment type Isd Fixed   [Isd] Short-time protection pick-up adjustment range 190 A   Short-time protection delay adjustment type tsd Fixed   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.05 kg Main - LV429772 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX100F   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 40 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 50825 kA at 480 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50822 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   Performance level F 36 kA 415 V AC   trip unit name Micrologic 2.2   trip unit technology Electronic   trip unit protection functions LSoI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-235 kA at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-24 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 50000 cycles   electrical durability 10000 cycles at 690 V In20000 cycles at 690 V In/230000 cycles at 440 V In50000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection   trip unit rating 40 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings   [Ir] long-time protection pick-up adjustment range 18...40 A   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 11 s at 7.2 x Ir16 s at 6 x Ir400 s at 1.5 x Ir   thermal memory 20 minutes before and after tripping   Short-time protection pick-up adjustment type Isd Adjustable 9 settings   [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir   Short-time protection delay adjustment type tsd Fixed   Instantaneous protection pick-up adjustment type Ii Fixed   [Ii] instantaneous protection pick-up adjustment range 600 A   earth-leakage protection Without   zone selective interlocking ZSI Without   Number of slots for electrical auxiliaries 5 slot(s)   local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.05 kg Main - LV430636  Range  Compact  Product Name  ComPact NSX100  Range of Product  Compact NSX100...250  Device short Name  NSX160F  Product or Component Type  Circuit Breaker  Device Application  Distribution  Number of Poles  3P  Protected poles Description  3t  [In] Rated Current  40 A at 40 °C  [Ue] Rated operational Voltage  690 V AC 50/60 Hz  Network Type  AC  Network Frequency  50/60 Hz  Suitability for Isolation  Yes conforming to EN/IEC 60947-2  Utilisation Category  Category A  [Icu] rated ultimate short-circuit breaking capacity  10 kA at 600 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2  Proformance Level  F 36 kA 415 V AC  Trip unit name  TM-D  Trip Unit Technology  Thermal-Magnetic  Trip unit protection functions  LI  Control Typer  Toggle  Circuit Breaker Mounting Mode  Fixed            Complementary  [Ui] rated insulation voltage  800 V AC 50/60 Hz  [Uimp] rated impulse withstand voltage  8 kV  [Ics] rated service short-circuit breaking capacity  35 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 KA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 85 KA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 22 KA at 525 V AC 50/60 Hz conforming to IEC 60947-2 30 KA at 500 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2  Mechanical durability  40000 Cycles  Electrical durability  7500 Cycles at 690 V In   15000 Cycles at 690 V In/2   20000 Cycles at 440 V In   40000 cycles at 440 V In/2  Mounting support  Backplate  Upside connection  Front  Downside connection  Front  Connection pitch  35mm  Protection type  L : for overload protection (thermal)   I : for short-circuit protection (magnetic)  Trip unit rating  40 A at 40°C  Long-time pick-up adjustment type Ir (thermal protection)  Adjustable  [Ir] long-time protection pick-up adjustment range  0.7 … 1 x In  Long-time protection delay adjustment type tr  Fixed  [tr] long-time protection delay adjustment range  120...400 S at 1.5 x In  15 s at 6 x Ir  Short-time protection pick-up adjustment type Isd  Fixed  [Isd] Short-time protection pick-up adjustment range  500A  Short-time protection delay adjustment type tsd  Fixed  Earth-leakage protection  Without  Number of slots for electrical auxiliaries  5 Slot(s)  Width (W)  105mm  Height (H)  161mm  Depth (D)  86mm  Product Weight  2.2kg  Main - LV430771 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX160F   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 100 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50822 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA at 480 V AC 50/60 Hz conforming to UL 50830 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2   Performance level F 36 kA 415 V AC   trip unit name Micrologic 2.2   trip unit technology Electronic   trip unit protection functions LSoI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-285 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-222 kA at 525 V AC 50/60 Hz conforming to IEC 60947-230 kA at 500 V AC 50/60 Hz conforming to IEC 60947-28 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 40000 cycles   electrical durability 7500 cycles at 690 V In15000 cycles at 690 V In/220000 cycles at 440 V In40000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection   trip unit rating 100 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings   [Ir] long-time protection pick-up adjustment range 40...100 A   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 11 s at 7.2 x Ir16 s at 6 x Ir400 s at 1.5 x Ir   thermal memory 20 minutes before and after tripping   Short-time protection pick-up adjustment type Isd Adjustable 9 settings   [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir   Short-time protection delay adjustment type tsd Fixed   Instantaneous protection pick-up adjustment type Ii Fixed   [Ii] instantaneous protection pick-up adjustment range 1500 A   earth-leakage protection Without   zone selective interlocking ZSI Without   Number of slots for electrical auxiliaries 5 slot(s)   local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.2 kg Main - LV430831 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX160F   product or component type Circuit breaker   device application Motor   Number of poles 3P   protected poles description 3t   [In] rated current 100 A at 65 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50822 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA at 480 V AC 50/60 Hz conforming to UL 50830 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2   Performance level F 36 kA 415 V AC   trip unit name MA   trip unit technology Magnetic   trip unit protection functions I   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-285 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-222 kA at 525 V AC 50/60 Hz conforming to IEC 60947-230 kA at 500 V AC 50/60 Hz conforming to IEC 60947-28 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 40000 cycles   electrical durability 7500 cycles at 690 V In15000 cycles at 690 V In/220000 cycles at 440 V In40000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type I : for short-circuit protection (magnetic)   trip unit rating 100 A at 65 °C   Short-time protection pick-up adjustment type Isd Adjustable   [Isd] Short-time protection pick-up adjustment range 9...14 x In   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.2 kg Main - LV430835 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSXm 160H   product or component type Circuit breaker   device application Motor   Number of poles 3P   protected poles description 3t   [In] rated current 100 A at 65 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50865 kA at 480 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-265 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2   Performance level H 70 kA 415 V AC   trip unit name MA   trip unit technology Magnetic   trip unit protection functions I   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA at 500 V AC 50/60 Hz conforming to IEC 60947-265 kA at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 40000 cycles   electrical durability 7500 cycles at 690 V In15000 cycles at 690 V In/220000 cycles at 440 V In40000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type I : for short-circuit protection (magnetic)   trip unit rating 100 A at 65 °C   Short-time protection pick-up adjustment type Isd Adjustable   [Isd] Short-time protection pick-up adjustment range 9...14 x In   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.2 kg   Main - LV431636  Range  Compact  Product Name  ComPact NSX100  Range of Product  Compact NSX100...250  Device short Name  NSX160F  Product or Component Type  Circuit Breaker  Device Application  Distribution  Number of Poles  3P  Protected poles Description  3t  [In] Rated Current  63A at 40 °C  [Ue] Rated operational Voltage  690 V AC 50/60 Hz  Network Type  AC  Network Frequency  50/60 Hz  Suitability for Isolation  Yes conforming to EN/IEC 60947-2  Utilisation Category  Category A  [Icu] rated ultimate short-circuit breaking capacity  85 KA at 240 V AC 50/60 Hz conforming to UL 508   22 KA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2   35 KA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2  36 KA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2   8 KA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2  85 KA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   35 KA at 480 V AC 50/60 Hz conforming to UL 508   30 KA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2   15 kA at 600 V AC 50/60 Hz conforming to UL 508  Proformance Level  F 36 kA 415 V AC  Trip unit name  TM-D  Trip Unit Technology  Thermal-Magnetic  Trip unit protection functions  LI  Control Typer  Toggle  Circuit Breaker Mounting Mode  Fixed  Complementary  [Ui] rated insulation voltage  800 V AC 50/60 Hz  [Uimp] rated impulse withstand voltage  8 kV  [Ics] rated service short-circuit breaking capacity  35 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2   36 KA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2   85 KA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   22 KA at 525 V AC 50/60 Hz conforming to IEC 60947-2   30 KA at 500 V AC 50/60 Hz conforming to IEC 60947-2   8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2  Mechanical durability  20000 Cycles  Electrical durability  5000 Cycles at 690 V In   10000 Cycles at 690 V In/2   10000 Cycles at 440 V In   20000 cycles at 440 V In/2  Mounting support  Backplate  Upside connection  Front  Downside connection  Front  Connection pitch  35mm  Protection type  L : for overload protection (thermal)   I : for short-circuit protection (magnetic)  Trip unit rating  63A at 40°C  Long-time pick-up adjustment type Ir (thermal protection)  Adjustable  [Ir] long-time protection pick-up adjustment range  0.7 … 1 x In  Long-time protection delay adjustment type tr  Fixed  [tr] long-time protection delay adjustment range  120...400 S at 1.5 x In  15 s at 6 x Ir  Short-time protection pick-up adjustment type Isd  Fixed  [Isd] Short-time protection pick-up adjustment range  500A  Short-time protection delay adjustment type tsd  Fixed  Earth-leakage protection  Without  Number of slots for electrical auxiliaries  5 Slot(s)  Width (W)  105mm  Height (H)  161mm  Depth (D)  86mm  Product Weight  2.2kg  Main - LV431772 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX250F   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 100 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50822 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA at 480 V AC 50/60 Hz conforming to UL 50830 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-215 kA at 600 V AC 50/60 Hz conforming to UL 508   Performance level F 36 kA 415 V AC   trip unit name Micrologic 2.2   trip unit technology Electronic   trip unit protection functions LSoI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-285 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-222 kA at 525 V AC 50/60 Hz conforming to IEC 60947-230 kA at 500 V AC 50/60 Hz conforming to IEC 60947-28 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 20000 cycles   electrical durability 5000 cycles at 690 V In10000 cycles at 690 V In/210000 cycles at 440 V In20000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection   trip unit rating 100 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings   [Ir] long-time protection pick-up adjustment range 40...100 A   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 11 s at 7.2 x Ir16 s at 6 x Ir400 s at 1.5 x Ir   thermal memory 20 minutes before and after tripping   Short-time protection pick-up adjustment type Isd Adjustable 9 settings   [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir   Short-time protection delay adjustment type tsd Fixed   Instantaneous protection pick-up adjustment type Ii Fixed   [Ii] instantaneous protection pick-up adjustment range 1500 A   earth-leakage protection Without   zone selective interlocking ZSI Without   Number of slots for electrical auxiliaries 5 slot(s)   local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.4 kg Main - LV431749 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX250F   product or component type Circuit breaker   device application Motor   Number of poles 3P   protected poles description 3t   [In] rated current 150 A at 65 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50822 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA at 480 V AC 50/60 Hz conforming to UL 50830 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-215 kA at 600 V AC 50/60 Hz conforming to UL 508   Performance level F 36 kA 415 V AC   trip unit name MA   trip unit technology Magnetic   trip unit protection functions I   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-285 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-222 kA at 525 V AC 50/60 Hz conforming to IEC 60947-230 kA at 500 V AC 50/60 Hz conforming to IEC 60947-28 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 20000 cycles   electrical durability 5000 cycles at 690 V In10000 cycles at 690 V In/210000 cycles at 440 V In20000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type I : for short-circuit protection (magnetic)   trip unit rating 150 A at 65 °C   Short-time protection pick-up adjustment type Isd Adjustable   [Isd] Short-time protection pick-up adjustment range 9...14 x In   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.4 kg