AJ&LI Enterprise
LV429833

NSX 100.160.250 N -Distribution/Motor

SKU: bc-620

$802.52

Currently out of stock — contact us for lead times

Ask a Question

Description

Main - LV429795 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX100N   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 100 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-220 kA at 600 V AC 50/60 Hz conforming to UL 50850 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   Performance level N 50 kA 415 V AC   trip unit name Micrologic 2.2   trip unit technology Electronic   trip unit protection functions LSoI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 50000 cycles   electrical durability 10000 cycles at 690 V In20000 cycles at 690 V In/230000 cycles at 440 V In50000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection   trip unit rating 100 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings   [Ir] long-time protection pick-up adjustment range 40...100 A   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 11 s at 7.2 x Ir16 s at 6 x Ir400 s at 1.5 x Ir   thermal memory 20 minutes before and after tripping   Short-time protection pick-up adjustment type Isd Adjustable 9 settings   [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir   Short-time protection delay adjustment type tsd Fixed   Instantaneous protection pick-up adjustment type Ii Fixed   [Ii] instantaneous protection pick-up adjustment range 1500 A   earth-leakage protection Without   zone selective interlocking ZSI Without   Number of slots for electrical auxiliaries 5 slot(s)   local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.05 kg Main - LV249797 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX100N   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 40 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-220 kA at 600 V AC 50/60 Hz conforming to UL 50850 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   Performance level N 50 kA 415 V AC   trip unit name Micrologic 2.2   trip unit technology Electronic   trip unit protection functions LSoI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 50000 cycles   electrical durability 10000 cycles at 690 V In20000 cycles at 690 V In/230000 cycles at 440 V In50000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection   trip unit rating 40 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings   [Ir] long-time protection pick-up adjustment range 18...40 A   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 11 s at 7.2 x Ir16 s at 6 x Ir400 s at 1.5 x Ir   thermal memory 20 minutes before and after tripping   Short-time protection pick-up adjustment type Isd Adjustable 9 settings   [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir   Short-time protection delay adjustment type tsd Fixed   Instantaneous protection pick-up adjustment type Ii Fixed   [Ii] instantaneous protection pick-up adjustment range 600 A   earth-leakage protection Without   zone selective interlocking ZSI Without   Number of slots for electrical auxiliaries 5 slot(s)   local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.05 kg Main - LV429847 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX100N   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 16 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-220 kA at 600 V AC 50/60 Hz conforming to UL 50850 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   Performance level N 50 kA 415 V AC   trip unit name TM-D   trip unit technology Thermal-magnetic   trip unit protection functions LI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 50000 cycles   electrical durability 10000 cycles at 690 V In20000 cycles at 690 V In/230000 cycles at 440 V In50000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (thermal)I : for short-circuit protection (magnetic)   trip unit rating 16 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable   [Ir] long-time protection pick-up adjustment range 0.7...1 x In   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 120…400 s at 1.5 x In15 s at 6 x Ir   Short-time protection pick-up adjustment type Isd Fixed   [Isd] Short-time protection pick-up adjustment range 190 A   Short-time protection delay adjustment type tsd Fixed   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.05 kg Main - LV430776 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX160N   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 100 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   Performance level N 50 kA 415 V AC   trip unit name Micrologic 2.2   trip unit technology Electronic   trip unit protection functions LSoI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 40000 cycles   electrical durability 7500 cycles at 690 V In15000 cycles at 690 V In/220000 cycles at 440 V In40000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection   trip unit rating 100 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings   [Ir] long-time protection pick-up adjustment range 40...100 A   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 11 s at 7.2 x Ir16 s at 6 x Ir400 s at 1.5 x Ir   thermal memory 20 minutes before and after tripping   Short-time protection pick-up adjustment type Isd Adjustable 9 settings   [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir   Short-time protection delay adjustment type tsd Fixed   Instantaneous protection pick-up adjustment type Ii Fixed   [Ii] instantaneous protection pick-up adjustment range 1500 A   earth-leakage protection Without   zone selective interlocking ZSI Without   Number of slots for electrical auxiliaries 5 slot(s)   local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.2 kg Main - LV430846 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX160N   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 40 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   Performance level N 50 kA 415 V AC   trip unit name TM-D   trip unit technology Thermal-magnetic   trip unit protection functions LI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 40000 cycles   electrical durability 7500 cycles at 690 V In15000 cycles at 690 V In/220000 cycles at 440 V In40000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (thermal)I : for short-circuit protection (magnetic)   trip unit rating 40 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable   [Ir] long-time protection pick-up adjustment range 0.7...1 x In   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 120…400 s at 1.5 x In15 s at 6 x Ir   Short-time protection pick-up adjustment type Isd Fixed   [Isd] Short-time protection pick-up adjustment range 500 A   Short-time protection delay adjustment type tsd Fixed   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.2 kg Main - LV430833 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX160N   product or component type Circuit breaker   device application Motor   Number of poles 3P   protected poles description 3t   [In] rated current 100 A at 65 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   Performance level N 50 kA 415 V AC   trip unit name MA   trip unit technology Magnetic   trip unit protection functions I   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 40000 cycles   electrical durability 7500 cycles at 690 V In15000 cycles at 690 V In/220000 cycles at 440 V In40000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type I : for short-circuit protection (magnetic)   trip unit rating 100 A at 65 °C   Short-time protection pick-up adjustment type Isd Adjustable   [Isd] Short-time protection pick-up adjustment range 9...14 x In   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.2 kg Main - LV431836 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX250N   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 63 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-215 kA at 600 V AC 50/60 Hz conforming to UL 508   Performance level N 50 kA 415 V AC   trip unit name TM-D   trip unit technology Thermal-magnetic   trip unit protection functions LI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 20000 cycles   electrical durability 5000 cycles at 690 V In10000 cycles at 690 V In/210000 cycles at 440 V In20000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (thermal)I : for short-circuit protection (magnetic)   trip unit rating 63 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable   [Ir] long-time protection pick-up adjustment range 0.7...1 x In   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 120…400 s at 1.5 x In15 s at 6 x Ir   Short-time protection pick-up adjustment type Isd Fixed   [Isd] Short-time protection pick-up adjustment range 500 A   Short-time protection delay adjustment type tsd Fixed   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.4 kg Main - LV431872 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX250N   product or component type Circuit breaker   device application Distribution   Number of poles 3P   protected poles description 3t   [In] rated current 100 A at 40 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-215 kA at 600 V AC 50/60 Hz conforming to UL 508   Performance level N 50 kA 415 V AC   trip unit name Micrologic 2.2   trip unit technology Electronic   trip unit protection functions LSoI   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 20000 cycles   electrical durability 5000 cycles at 690 V In10000 cycles at 690 V In/210000 cycles at 440 V In20000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type L : for overload protection (long time)So : for short time short-circuit protection with fixed delayI : for instantaneous short-circuit protection   trip unit rating 100 A at 40 °C   Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings   [Ir] long-time protection pick-up adjustment range 40...100 A   Long-time protection delay adjustment type tr Fixed   [tr] long-time protection delay adjustment range 11 s at 7.2 x Ir16 s at 6 x Ir400 s at 1.5 x Ir   thermal memory 20 minutes before and after tripping   Short-time protection pick-up adjustment type Isd Adjustable 9 settings   [Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir   Short-time protection delay adjustment type tsd Fixed   Instantaneous protection pick-up adjustment type Ii Fixed   [Ii] instantaneous protection pick-up adjustment range 1500 A   earth-leakage protection Without   zone selective interlocking ZSI Without   Number of slots for electrical auxiliaries 5 slot(s)   local signalling Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.4 kg Main - LV431752 range ComPact   product name ComPact NSX   range of product ComPact NSX100...250   device short name NSX250N   product or component type Circuit breaker   device application Motor   Number of poles 3P   protected poles description 3t   [In] rated current 220 A at 65 °C   [Ue] rated operational voltage 690 V AC 50/60 Hz   network type AC   network frequency 50/60 Hz   suitability for isolation Yes conforming to EN/IEC 60947-2   utilisation category Category A   [Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA at 480 V AC 50/60 Hz conforming to UL 50836 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-215 kA at 600 V AC 50/60 Hz conforming to UL 508   Performance level N 50 kA 415 V AC   trip unit name MA   trip unit technology Magnetic   trip unit protection functions I   control type Toggle   Circuit breaker mounting mode Fixed   Complementary [Ui] rated insulation voltage 800 V AC 50/60 Hz   [Uimp] rated impulse withstand voltage 8 kV   [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-235 kA at 525 V AC 50/60 Hz conforming to IEC 60947-236 kA at 500 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-290 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2   mechanical durability 20000 cycles   electrical durability 5000 cycles at 690 V In10000 cycles at 690 V In/210000 cycles at 440 V In20000 cycles at 440 V In/2   mounting support Backplate   upside connection Front   downside connection Front   connection pitch 35 mm   protection type I : for short-circuit protection (magnetic)   trip unit rating 220 A at 65 °C   Short-time protection pick-up adjustment type Isd Adjustable   [Isd] Short-time protection pick-up adjustment range 9...14 x In   earth-leakage protection Without   Number of slots for electrical auxiliaries 5 slot(s)   Width (W) 105 mm   Height (H) 161 mm   Depth (D) 86 mm   net weight 2.4 kg