NG125 - Type MA
SKU: bc-628
$161.45
Currently out of stock — contact us for lead times
Description
Main - 18868 Miniature Circuit-Breaker range of product NG125 range Acti 9 product name Acti9 NG125LMA product or component type Miniature circuit-breaker device short name NG125LMA device application Motor poles description 2P number of protected poles 2 [In] rated current 4 A at 40 °C network type AC trip unit technology Magnetic curve code MA breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-240 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-250 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-215 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 Complementary network frequency 50/60 Hz [Ue] rated operational voltage 380...415 V AC 50/60 Hz500 V AC 50/60 Hz220...240 V AC 50/60 Hz440 V AC 50/60 Hz magnetic tripping limit 12 x In [Ics] rated service breaking capacity 75 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz37.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz30 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz11.25 kA 75 % conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 [Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2 contact position indicator Yes control type Manual tripping testToggle local signalling ON/OFF indicationTrip indicator mounting mode Clip-on mounting support 35 mm symmetrical DIN rail comb busbar and distribution block compatibility YES 9 mm pitches 6 height 103 mm width 54 mm depth 81 mm net weight 0.48 kg mechanical durability 20000 cycles electrical durability 10000 cycles provision for padlocking Padlockable locking options description Integrated padlocking connections - terminals Tunnel type terminals1.5…50 mm² rigidTunnel type terminals1…35 mm² flexible wire stripping length 20 mm tightening torque 3.5 N.m earth-leakage protection Separate block Main - 18879 Miniature Circuit-Breaker range of product NG125 range Acti 9 product name Acti9 NG125LMA product or component type Miniature circuit-breaker device short name NG125LMA device application Motor poles description 3P number of protected poles 3 [In] rated current 4 A at 40 °C network type AC trip unit technology Magnetic curve code MA breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-240 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-250 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-215 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 Complementary network frequency 50/60 Hz [Ue] rated operational voltage 380...415 V AC 50/60 Hz500 V AC 50/60 Hz220...240 V AC 50/60 Hz440 V AC 50/60 Hz magnetic tripping limit 12 x In [Ics] rated service breaking capacity 75 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz37.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz30 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz11.25 kA 75 % conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 [Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2 contact position indicator Yes control type ToggleManual tripping test local signalling Trip indicatorON/OFF indication mounting mode Clip-on mounting support 35 mm symmetrical DIN rail comb busbar and distribution block compatibility YES 9 mm pitches 9 height 103 mm width 81 mm depth 81 mm net weight 0.72 kg mechanical durability 20000 cycles electrical durability 10000 cycles provision for padlocking Padlockable locking options description Integrated padlocking connections - terminals Tunnel type terminals1.5…50 mm² rigidTunnel type terminals1…35 mm² flexible wire stripping length 20 mm tightening torque 3.5 N.m earth-leakage protection Separate block