AJ&LI Enterprise
ATS22D17Q

415V Line Voltage

SKU: bc-650

$770.87

Currently out of stock — contact us for lead times

Ask a Question

Description

Main - ATS22D17Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 4 kW 230 V7.5 kW 400 V7.5 kW 440 V   factory setting current 14.8 A   power dissipation in W 39 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 17 A for connection in the motor supply line for standard applications   IP degree of protection IP20   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection In the motor supply lineTo the motor delta terminals   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 265 mm   width 130 mm   depth 169 mm   net weight 7 kg   Motor power range AC-3 4…6 kW at 200…240 V 3 phases7…11 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22D32Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 15 kW 400 V15 kW 440 V7.5 kW 230 V   factory setting current 28.5 A   power dissipation in W 44 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 32 A for connection in the motor supply line for standard applications   IP degree of protection IP20   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection In the motor supply lineTo the motor delta terminals   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 265 mm   width 130 mm   depth 169 mm   net weight 7 kg   Motor power range AC-3 7…11 kW at 200…240 V 3 phases15…25 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22D47Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 11 kW 230 V22 kW 400 V22 kW 440 V   factory setting current 42 A   power dissipation in W 48 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 47 A for connection in the motor supply line for standard applications   IP degree of protection IP20   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection To the motor delta terminalsIn the motor supply line   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 265 mm   width 130 mm   depth 169 mm   net weight 7 kg   Motor power range AC-3 7…11 kW at 200…240 V 3 phases15…25 kW at 380…440 V 3 phases   motor starter type Soft starter   Main - ATS22D62Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 15 kW 230 V30 kW 400 V30 kW 440 V   factory setting current 57 A   power dissipation in W 59 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 62 A for connection in the motor supply line for standard applications   IP degree of protection IP20   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection To the motor delta terminalsIn the motor supply line   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 295 mm   width 145 mm   depth 207 mm   net weight 12 kg   Motor power range AC-3 15…25 kW at 200…240 V 3 phases30…50 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22D75Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 37 kW 400 V37 kW 440 V18.5 kW 230 V   factory setting current 69 A   power dissipation in W 63 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 75 A for connection in the motor supply line for standard applications   IP degree of protection IP20   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection In the motor supply lineTo the motor delta terminals   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 295 mm   width 145 mm   depth 207 mm   net weight 12 kg   Motor power range AC-3 15…25 kW at 200…240 V 3 phases30…50 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22D88Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 22 kW 230 V45 kW 400 V45 kW 440 V   factory setting current 81 A   power dissipation in W 66 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 88 A for connection in the motor supply line for standard applications   IP degree of protection IP20   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection To the motor delta terminalsIn the motor supply line   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 295 mm   width 145 mm   depth 207 mm   net weight 12 kg   Motor power range AC-3 15…25 kW at 200…240 V 3 phases30…50 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22C11Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 39 kW 230 V55 kW 400 V55 kW 440 V   factory setting current 100 A   power dissipation in W 73 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 110 A for connection in the motor supply line for standard applications   IP degree of protection IP20   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection In the motor supply lineTo the motor delta terminals   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 356 mm   width 150 mm   depth 229.5 mm   net weight 18 kg   Motor power range AC-3 30…50 kW at 200…240 V 3 phases55…100 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22C14Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 37 kW 230 V75 kW 400 V75 kW 440 V   factory setting current 131 A   power dissipation in W 82 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 140 A for connection in the motor supply line for standard applications   IP degree of protection IP00   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection In the motor supply lineTo the motor delta terminals   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 356 mm   width 150 mm   depth 229.5 mm   net weight 18 kg   Motor power range AC-3 30…50 kW at 200…240 V 3 phases55…100 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22C17Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 45 kW 230 V90 kW 400 V90 kW 440 V   factory setting current 162 A   power dissipation in W 91 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 170 A for connection in the motor supply line for standard applications   IP degree of protection IP00   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection To the motor delta terminalsIn the motor supply line   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 356 mm   width 150 mm   depth 229.5 mm   net weight 18 kg   Motor power range AC-3 30…50 kW at 200…240 V 3 phases55…100 kW at 380…440 V 3 phases   motor starter type Soft starter   Main - ATS22C21Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 110 kW 400 V110 kW 440 V55 kW 230 V   factory setting current 195 A   power dissipation in W 117 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 210 A for connection in the motor supply line for standard applications   IP degree of protection IP00   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection To the motor delta terminalsIn the motor supply line   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 425 mm   width 206 mm   depth 299 mm   net weight 33 kg   Motor power range AC-3 55…100 kW at 200…240 V 3 phases110…220 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22C25Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 132 kW 400 V132 kW 440 V75 kW 230 V   factory setting current 233 A   power dissipation in W 129 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 250 A for connection in the motor supply line for standard applications   IP degree of protection IP00   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection In the motor supply lineTo the motor delta terminals   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 425 mm   width 206 mm   depth 299 mm   net weight 33 kg   Motor power range AC-3 55…100 kW at 200…240 V 3 phases110…220 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22C32Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 160 kW 400 V160 kW 440 V90 kW 230 V   factory setting current 285 A   power dissipation in W 150 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 320 A for connection in the motor supply line for standard applications   IP degree of protection IP00   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection To the motor delta terminalsIn the motor supply line   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 425 mm   width 206 mm   depth 299 mm   net weight 33 kg   Motor power range AC-3 55…100 kW at 200…240 V 3 phases110…220 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22C41Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 110 kW 230 V220 kW 400 V220 kW 440 V   factory setting current 388 A   power dissipation in W 177 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 410 A for connection in the motor supply line for standard applications   IP degree of protection IP00   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection To the motor delta terminalsIn the motor supply line   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 425 mm   width 206 mm   depth 299 mm   net weight 33 kg   Motor power range AC-3 110…220 kW at 380…440 V 3 phases110…220 kW at 200…240 V 3 phases   motor starter type Soft starter Main - ATS22C48Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 132 kW 230 V250 kW 400 V250 kW 440 V   factory setting current 437 A   power dissipation in W 218 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 480 A for connection in the motor supply line for standard applications   IP degree of protection IP00   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection In the motor supply lineTo the motor delta terminals   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 455 mm   width 304 mm   depth 339.7 mm   net weight 50 kg   Motor power range AC-3 110…220 kW at 200…240 V 3 phases250…500 kW at 380…440 V 3 phases   motor starter type Soft starter Main - ATS22C59Q range of product Altistart 22   product or component type Soft starter   product destination Asynchronous motors   product specific application Pumps and fans   component name ATS22   network number of phases 3 phases   [Us] rated supply voltage 230...440 V - 15...10 %   motor power kW 160 kW 230 V315 kW 400 V355 kW 440 V   factory setting current 560 A   power dissipation in W 251 W for standard applications   utilisation category AC-53A   type of start Start with torque control (current limited to 3.5 In)   IcL starter rating 590 A for connection in the motor supply line for standard applications   IP degree of protection IP00   Complementary assembly style With heat sink   function available Internal bypass   supply voltage limits 195…484 V   supply frequency 50...60 Hz - 10...10 %   network frequency 45...66 Hz   device connection To the motor delta terminalsIn the motor supply line   [Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz   control circuit consumption 20 W   discrete output number 2   discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/ORelay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O   minimum switching current 100 mA at 12 V DC (relay outputs)   maximum switching current 5 A 250 V AC resistive 1 relay outputs5 A 30 V DC resistive 1 relay outputs2 A 250 V AC inductive 0.4 20 ms relay outputs2 A 30 V DC inductive 7 ms relay outputs   discrete input number 3   discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm   discrete input voltage 24 V <= 30 V   discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA   output current 0.4...1 Icl adjustable   PTC probe input 750 Ohm   communication port protocol Modbus   connector type 1 RJ45   communication data link Serial   physical interface RS485 multidrop   transmission rate 4800, 9600 or 19200 bps   installed device 31   protection type Phase failure: lineThermal protection: motorThermal protection: starter   marking CE   type of cooling Forced convection   operating position Vertical +/- 10 degree   height 455 mm   width 304 mm   depth 339.7 mm   net weight 50 kg   Motor power range AC-3 110…220 kW at 200…240 V 3 phases250…500 kW at 380…440 V 3 phases   motor starter type Soft starter